Stabilizer, Stabilizers, 3 Phase Servo Control Stabilizer, Stabilizer Manufacturer, Mumbai, India

Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

 


STABILIZER

3 PHASE SERVO CONTROL STABILIZER

GENERAL  SPECIFICATION

Input Voltage Range

300v-460v Ac 3phase 50hz/60hz Phase To Phase

Other Input Ranges

340v-480v Ac/ 360v-460v Ac

Output Voltage 3 Phase

415v Ac

System

Unbalanced 4 Wire :R Y B N

Connection

Star

Operating Frequency

47hz To 53hz

Out Put  Voltage  Adjestable

380v To 415v In 3 Phase

Out Put  Voltage  Regulation

+/-1 %(No Load)

Out Put  Voltage  Regulation

+/-1%(Full Load)

Over Load  Capacity

120%

Correction Rate

60v/Second-3 Phase

Waveform Distortion

Nil

Out Put Waveform

True Reproduction Of Input

Insulation

Class ‘F’

Short Ckt Period & Percentage

300% For 45 C

Normal Operation Temperature

0 To 45c

Type Of Cooling

Natural Air Cooled Up To 150 Kva

Mode Of Systme

Fully Atomatics / Manual

Protection

  • LOW VOLTAGE PROTECTION
  • HIGH VOLTAGE PROTECTION
  • OVERLOAD PROTECTION WITH MCB/MCCB
  • SHORT CIRCUIT PROTECTION
  • SINGLE PHASING PREVENTER

PANEL CONTROL

       • INPUT/OUTPUT SELECT SWITCH
       • AUTO/MANUAL SELECT SWITCH
       • INCREASE/DECREASE SWITCH TO CONTROL THE OUYPUT VOLTAGE IN MANUAL MODE
       • VOLT ADJEST TO SET REQUIRED OUTPUT VOLTAGE IN AUTO MODE

PANEL INDICATIOR

  • INPUT-ON
  • OUTPUT-ON
  • INPUT-LOW
  • INPUT-HIGH
  • OUTPUT-CUT OFF

PANEL METERS

  • VOLTMETER WITH SELECTOR SWITCH TO READ INPUT/OUTPUT VOLTAGE
  • AMMETER WITH SELECTOR SWITCH (FROM 15KVA ONWARD)
  • INPUT/OUTPUT CONNECTION: SEPARATE CABLE ENTRY BOX IS PROVIDED

SALIENT FEATURES

  1. HIGH RALIABILITY:
  2. USE SOLID STAT CONTROL CIRCUIT,NO RELAY, NO WARM UP TIME ,SYNCHROUNS MOTOR DRIVE.
  3. TROUBLE FREE OPERATION
  4. QUICK RESPONSE TIME 10MILL SEC (HALF CYCLE)
  5. ALL TRANSFORMER ARE COPPER WOUND
  6. EXCELLENT REGULATION AS HIGH AS +/- O.5%
  7. ZERO WAVEFORM DISTORTION
  8. UNEFFECTED BY LOAD POWER FACTOR
  9. RUGGEDISEED CONSTRUCTION
  10. NO LOAD LOSS ARE VERY LOW
  11. VERY WIDE INPUT OPERATING RANGES
  12. INDIVIDUAL PHASE CONTROL IS PROVIDED
  13. CABLE GLAND IS PROVIDED FOR INPUT/OUTPUT
  14. FLOOR MOUNTED/FREE ON WHEEL

DIMENSION OF 3 PHASE SERVO CONTROL STABILIZER

Capacity
In kva 3phase

input:300-460v
output:415v

L

W

H

Kg

3kva

450

410

850

65

6 kva

450

410

850

80

10 kva

470

480

1025

90

12 kva

470

480

1025

120

15 kva

470

480

1025

140

20 kva

475

525

1245

170

22.5 kva

540

525

1245

175

25 kva

540

525

1245

190

30 kva

540

525

1450

225

35 kva

540

525

1450

230

40 kva

540

620

1450

289

45 kva

620

620

1450

300

50 kva

620

620

1300

320

60 kva

620

550

1300

360

75 kva

620

600

1300

430

80 kva

1400

600

1300

465

90 kva

1460

600

1300

475

100 kva

1460

600

1300

650

125 kva

1460

710

1610

675

150 kva

1460

710

1610

675

1 PHASE STABILISER

Input Voltage Range

170v-270 / 140v-270v / 90v-270v.

Frequency

50hz.

Out Put Voltage

230v

Output Voltage Regulation

+/-1% Of The Set Output Voltage Over The Specified Input Range From No Load To Full Load.

Output Waveform

True Reproduction Of Input.No Distortion Introduced

Effect Of Load Powerfacter

Nill

Efficiency

Better Than 95%

Correction Rate

35v/Sec

Control

Automatic/Manual. In Case Of Auto Failuer,Output Can Be Increased Or Decreased In Manual Moad

Motor

Rugged A.C Syncronous Motor

Meter

Analog,A/C Voltmeter For Reading Input/Output Voltage, A/C  Ameter For Reading Input/Output

PROTECTION

  • LOW VOLTAGE PROTECTION
  • HIGH VOLTAGE PROTECTION
  • OVERLOAD PROTECTION WITH MCB/MCCB
  • SHORT CIRCUIT PROTECTION
  • SINGLE PHASING PREVENTER

PANEL CONTROL

  • INPUT/OUTPUT SELECT SWITCH
  • AUTO/MANUAL SELECT SWITCH
  • INCREASE/DECREASE SWITCH TO CONTROL THE OUYPUT
    VOLTAGE IN MANUAL MODE
  • VOLT ADJEST TO SET REQUIRED OUTPUT VOLTAGE IN AUTO MODE

PANEL INDICATION

  • INPUT-ON
  • OUTPUT-ON
  • INPUT-LOW
  • INPUT-HIGH
  • OUTPUT-CUTOFF

PANEL METERS

  • VOLTMETER WITH SELECTOR SWITCH TO READ INPUT/OUTPUT VOLTAGE
  • AMMETER WITH SELECTOR SWITCH (FROM 15KVA ONWARD)

INPUT/OUTPUT CONNECTION

SEPARATE CABLE ENTRY BOX IS PROVIDED

DIMENSION OF 1 PHASE STABILIZER

1KVA

170X300X250

2KVA

220X300X275

3KVA

250X425X275

4KVA

250X425X300

5KVA

250X425X300

7.5KVA

440X450X400

10KVA

440X450X400

15KVA

550X575X400

20KVA

650X675X500

25KVA

650X675X500

 SMPS
 UPS & INVERTOR
 AUTO TRANSFORMER
 BATTARY CHARGER
 TOROIDAL TRANSFORMER
 STABILIZER
 CONSTANT VOLTAGE TRANSFORMER
   

Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

 

 
   
 
Designed & Hosted by : MID   Promoted by : GID